
Lithium Battery LI23S002A Use For Mindray BeneView T5 T6 T8 Patient Monitor
The Mindray BeneView T5, T6, and T8 patient monitors use rechargeable lithium-ion batteries that offer several key features.
Firstly, these batteries have a high energy density, allowing them to store a significant amount of power in a small, lightweight package. This makes the monitors more portable and easier to move around in clinical settings.
Secondly, the batteries have a long lifespan and can be recharged many times before needing to be replaced. This reduces the overall cost of ownership and minimizes environmental waste.
Thirdly, the batteries are designed with safety in mind and incorporate protection features such as overcharge, over-discharge, and short-circuit protection to prevent damage to the battery or the monitor.
Finally, the batteries have a fast charging time and can be fully charged in a relatively short period, allowing the monitors to be quickly returned to service.
The batteries in the Mindray BeneView T5, T6, and T8 monitors can be replaced easily if they fail or reach the end of their lifespan. Mindray recommends that only authorized service personnel replace the batteries to ensure proper installation and to maintain the safety and performance of the monitor.
To replace the battery, the service personnel will typically remove the back cover of the monitor and disconnect the old battery from the internal wiring harness. They will then install the new battery and reassemble the monitor. Mindray provides detailed instructions on battery replacement in the user manual or service manual for each monitor model.
The lifespan of the batteries in the Mindray BeneView T5, T6, and T8 monitors will depend on various factors, including usage patterns, charging habits, and storage conditions. Over time, the battery's capacity will gradually decrease, and it will eventually need to be replaced.
Mindray does not provide a specific timeframe for battery replacement since it will vary depending on these factors. However, they recommend that the batteries be regularly inspected and tested to ensure that they are functioning correctly. If the battery's capacity has significantly decreased or it fails to hold a charge, it should be replaced promptly to avoid downtime or potential safety issues.
Authorized service personnel can perform battery testing and replacement, and they can also provide guidance on battery maintenance and replacement schedules based on the specific usage patterns and conditions of the monitor.
Recommendations for maintenance schedules for the batteries in the Mindray BeneView T5, T6, and T8 monitors.
Charge the battery regularly: Lithium-ion batteries should be charged regularly to maintain their health and prolong their lifespan. Mindray recommends that the battery be charged to full capacity at least once every three months, even if the monitor is not in use.
Avoid overcharging: Overcharging can damage the battery and reduce its lifespan. Mindray's monitors are designed to prevent overcharging by automatically stopping the charging process when the battery is full.
Store the battery correctly: If the monitor is not in use for an extended period, it is essential to store the battery properly. Mindray recommends storing the battery in a cool, dry place away from direct sunlight and extreme temperatures.
Perform regular battery testing: To ensure that the battery is functioning correctly, it is essential to perform regular battery testing. Mindray recommends that the battery be tested at least once a year or more frequently if the monitor is in heavy use.
Replace the battery when necessary: Lithium-ion batteries have a limited lifespan, and they will eventually need to be replaced. Mindray recommends that the battery be replaced promptly if it fails to hold a charge or if its capacity has significantly decreased.
These guidelines can help you develop a maintenance plan for your batteries, but it's important to consult the user manual or service manual for your specific monitor model for more detailed guidance. Additionally, authorized service personnel can provide expert advice on battery maintenance and replacement schedules based on your specific usage patterns and conditions.
Guangzhou YIGU Medical Equipment Service Co.,Ltd
Guangzhou YIGU Medical Equipment Service Company is the medical maintenance third-party service that devote to develop the most professional, most well-equipped service.We provide service for various hospitals, clinics, original agents, schools, the third-party companies and oversea clients in medical equipment domain.
As a professional medical equipment service company, to provide a superior product and quality service to each client is our biggest aim. We always work hard for a long-term and win-win cooperation.
Service spirit: Honesty and pragmatic, efficiency and innovation;
Service concept: Courage and wise, professional service.
一. Monitoring Equipment
1. Selling and replacing for Electrocardiogram Monitoring/ Defibrillator/ EGG/ Fetal Monitor Repair and parts.
2. Inspection Judgment/ Chip/Mainboard, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display,Keyboat Plate, Specification PCB, Rotary Knob Maintenrance.
3.Selling and replacing all kinds of PCB, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display,Keyboat Plate, Specification PCB, Rotary Knob.
4.Monitor/ Electrocardiograph for renting,maintenance, guarantee repairing and training.
Included brands: GE, , Spacelabs, Siemens, Mindray, ZOLL, Endoscopy, Tyco, NIHON KOHDEN, , Promeco etc.
Technological advantage: M3001A Part Repairing
Brand | Model |
GE
| DASH1800、DASH2000、DASH2500、DASH3000、DASH4000、 DASH5000、PRO300、PRO400、PRO1000、EAGLE1000、 EAGLE3000、EAGLE4000、SOLAR8000、SOLAR8000i、SOLAR8000M、451N、451SL、450SL TRAM、S/5、Datex-Ohmeda、Cardiocap/5、B40、Transport Pro、MAC500、MAC800、MAC1200、MAC1600、MAC3500、MAC5000、MAC5500、Resonder3000、CARDIOSERV、Corometrics Model 2120is |
| MP20、MP30、MP40、MP50、MP60、MP70(M3000A、M3001A、 M3014A、M3015A、M3016A、M3000-60001、M3000-60002、M3000-60003)、A1、A3、C1、C3、M1723B、M1722A、M4735A、M3535A、M135A、VM4、VM6、VM8、VS3、MP5、M2、M3046A |
Spacelabs
| 1050、90369、91369、Ultraview SL、 90496、91496、mCare300 |
Siemens
| SC60002、SC6000、SC7000、SC60002XL |
Tyco
| NBP40、N595、N600 |
MINDRAY
| PM-7000、PM-8000、PM-9000、MEC-1000、MEC-2000、 PM-7000 Express、PM-8000 Express、PM-9000 Express、PM-60、VS-600、VS-800、VS-900、T5、T6、T8 |
ZOLL
| Defibrillator |
| Radical-7、MS-201、MS-11、MS-7、MS-5 |
| ||
BRAND |
| |
GE | DASH1800,DASH2000,DASH2500,DASH3000,DASH4000,DASH5000, | |
| MP20,MP30,MP40,MP50,MP60,MP70,MP80,MP90,FM20,M4735A,M1351A, | |
NIHON KOHDEN |
| |
Spacelabs | 1050,90369,91369,Ultraview SL, 0496,91496,mCare300 | |
Siemens | SC60002,SC6000,SC7000,SC60002XL | |
Mindray | PM-6000,PM-7000,PM-8000,PM-9000,MEC-1000,MEC-2000, | |
Tyco | NBP4000,NBP4000C | |
| ||
BRAND |
| |
GE | Ohmeda TuffSat ,Ohmeda 3900 | |
Tyco | NBP-40,N-65,NBP-390,N-395,N-550,N-560, | |
Rad-8 SPO2 oximeter ,Radical-7(MS-2011,MS-11,MS-7,MS-5) | ||
NIHON KOHDEN | BSM-1753A
|
二. Ultrasound
New/used/compatible probe/ ultrasound/ PCB for repairing and selling.
Included brands: , GE, Toshiba, Siemens, Medison, Biosound, Hitachi, HP, ATL, ALOKA, etc.
The severice for B Ultrasound probe repairing/ Color Doppler Ultrasound probe repairing are included:
Project Advantages: More 100pcs used B Ultrasound Probe off the shelf for renting and back up.
Ultrasound
| ||
BRAND | MODEL | |
GE | Voluson E6 ,VolusonE8,LOGIQ180,LOGIQ200,LOGIQ400,LOGIQ500,LOGIQ3,LOGIQ5,LOGIQ7,LOGIQ9,LOGIQ E,LOGIQ BOOK XP,VIVID3,VIVID4,VIVID5,,VIVID i, VIVID E9,VIVID 7 | |
IU22,IE33,,D3,HD6,HD7,HD9,HD11,HD15,HD11XE, HDI4000,HDI5000,SONOS4500,SONOS5500,Envisor | ||
SIEMENS | ACUSON X150 ,ACUSON X300,ACUSON X300 PE,SONOLINE G20 ,SONOLINE G40,SONOLINE G50,SONOLINE G60,PRIMIER,Sequoia 512,Acuson CV70,Sonoline Premier(G40),acuson_antares | |
MEDISON |
| |
Mindray | DP3300,DP6600,DP7700,DP8800,DP9900,N80, M5,DC-3, DC-6 | |
ESAOTE | AU3,AU4,AU5,DU3,DU4,DU5,DU8 | |
SONOSITE
| TITAN | |
ALOKA | Prosound SSD-4000,SSD-240,SSD-260,SSD-280, SSD-633,SSD-650,SSD-725,SSD-830,SSD-870,SSD-1000,SSD-1400,SSD-1700,SSD-5000,SSD-7000 | |
Toshiba | SSA-770A,SSA-580,SSH-140,SSA-270A,SSA-340A,SSA-350A,SSA-270,SSH-140A,250A nemio17 |