
Bioilght Li-ion Battery Pack Model : LB-08 Rate : 11.1Vdc 5200mAh 57.72Wh PN : 12-100-0003
Product Description:
No. | PN | Use for GE monitor DASH3000/4000/5000/2500 ,SOLAR8000/8000M,GE S/5 AM/CAM,B20/30/40/450/650/1800 | Description |
1 | 2017003-001 | GE Original US Adult 5-lead Leadwire 3.6M #2017003-001 | CABLE ASSY ECG MLT-LNK 3/5 LEAD 3.6M AHA |
2 | 412681-001 | GE Original US 5-lead Leadwire 74CM/ 29 inches #412681-001 | LDWR AHA 5LD GRAB SH MOLDED |
3 | 411200-001 | GE Original US Adult Detachable Multi-Link Leadwire Set 5-lead 74CM/ 29 inches 74CM #411200-001 | Ldwr Set, Multi-Link Snap 29In AHA |
4 | 2006644-001 | GE Original SpO2 Leadwire 11 Needles Covidien Oxismart XL 2.9M #2006644-001 | Covidien Interface Cable |
5 | 2023211-001 | DASH2500 DASH1800 OXIMAX Can't use GE Original Covidien Oxismart XL 7 Needles Adult SpO2 Probe 1m #2023211-001 | Covidien Compatible Finger Sensor,with DB9 connector 1M |
6 | 2021406-001 | DASH2500 DASH1800 11 Needles GE Original SpO2 Leadwire Covidien OXIMAX 3M #2021406-001 | CABLE ASSY SPO2 Covidien OXIMAX 3M |
7 | DS100A | DASH2500 DASH1800 Covidien OXIMAX or Covidien Oxismart XL GE Original 7 Needles Adult SpO2 Probe #DS100A | DS1--A Covidien DuraSensor Reusable Finger Probe DS100A (1/box) |
8 | TS-F4-GE | GE B Series monitor,Ohmeda, 11 Needles GE OriginalAdult SpO2 Probe #TS-F4-GE | Ohmeda SPO2 Finger Sensor |
9 | 2017008-001 | GE Original Adult Blood Pressure Tube #2017008-001 | NIBP Dual Tube BP Tubing, Adult 3.6M for Dash and Tram |
10 | 2203 | GE Origianl Adult Cuff 23-33CM #2203 | DURA-CUF* Cuff, Adult, 2-Tube Sub-Min, Navy, |
11 | 30344030 | GE Original CARDIOSERV Defibrillator Battery 12V 1200mAh #30344030 | CARDIOSERV battery BTRY RECHGR NICD SCP |
12 | 21730403 | GE Original CARDIOSERV Defibrillator Paddles #21730403 | CARDIOSERV PADDLE PAIR DEFIB CSERV |
13 | 2029893-001 | GE Original MAC1200,MAC800 ECG Machine 10 Lead 14 Needles #2029893-001 | MAC1200 MAC800 Cable,Leadwire |
14 | 2037082-001 | GE Original MAC800 ECG Battery 7.2V 4500mAh 33Wh #2037082-001 | MAC800 battery |
15 | 2016560-002 | GE Original MAC5000 ECG Main Line 4.6m #2016560-002 | MAC5000 CABLE ASSY HOST CASE |
16 | 2016032-001 | GE Original CAM14 CAM Leadwire,Banana,10 Lead 90CM #2016032-001 | CAM 14 Leadwire Set, 10 Lead, Banana, AHA, Mixed Lengths |
17 | 2042686-002 | GE Original SEER Light7 EGC #2042686-002 #2008594-002 #2008596-001 | SEER Light patient cable 3 Channel |
18 | 5700HAX | GE Original CORO170 US 12 Needles #5700HAX | CORO170 U/S XDCR WATERTIGHT BUTTON 8' CABLE |
19 | 2264HAX | GE Original CORO170 Probe TOCO #2264HAX | CORO170 TOCO XDCR WATERTIGHT BUTTON 8' CABLE |
20 | 2003425-001 | GE Original Leadwire 10 Lead #2003425-001 | CABLE LEAD SET, ECG, 72 in. WIRES |
About us
Guangzhou YIGU Medical Equipment Service Co.,Ltd is a third party medical equipment maintenance service provider. In line with the service spirit of “ honest and pragmatic, efficient and innovative” and the maintenance concept of “bold and careful, professional service”, our company serves the medical equipment field of major hospitals, clinics, original factory agents, universities and international customers in the world. Our company will wholeheartedly provide customers with the best quality products and services, and pursuit win-win cooperation, mutual benefit and common development.
Common Faults Repair
1. Unbootable/ Unable to boot up 2. The module ( M3001A ) can’t detect blood pressure.
3. The module can’t be connected. 4. Automatically disconnect.
5. The sphygmomanometer has a leak. 6. NIBP equipment failure.
7. Unable to contact. 8. Error reporting MMS disconnected.
9. False alarm MMS pull out. 10. Can’t load out.
11. ECG malfunctions. 12. ECG equipment out of order.
13. Software upgrades. 14. NIBP fails to inflate.
15. IBP equipment faults. 16. M3012A module can’t be detected.
17. Automatically restart. 18. The encoder can’t work.
19. Blue screen appears after startup. 20. No ECG signal.
21. Unable to enter the select menu. 22. Alarm occurs when starting up, and the failure light is on.
23. Report CO2 plugging. 24. MMSL developing module faults.
25. M3015A / M3001A module faults. 26. No power display light.
27. NBP equipment faults. 28. ECG and oximeter equipment faults.
29. LCD lamp aging. 30. Inflated blood pressure does not indicate a number.
31. The key plate is out of order. 32. Encoder failure.
33. Can’t inflate. 34. NIBP equipment faults.
35. SP O2 and ECG equipment fault. 36. Unable to charge.
37. The touch screen can’t work. 38. The screen shows double image.
39. Error code 1000. Error code 20004. 40. No alarm sounds.
| |
GE |
|
Nihon Kohden |
|
Mindray |
|
Spacelabs |
|
Siemens |
|
Tyco |
|
Guangzhou YIGU Medical Equipment Service Co.,Ltd
Guangzhou YIGU Medical Equipment Service Company is the medical maintenance third-party service that devote to develop the most professional, most well-equipped service.We provide service for various hospitals, clinics, original agents, schools, the third-party companies and oversea clients in medical equipment domain.
As a professional medical equipment service company, to provide a superior product and quality service to each client is our biggest aim. We always work hard for a long-term and win-win cooperation.
Service spirit: Honesty and pragmatic, efficiency and innovation;
Service concept: Courage and wise, professional service.
一. Monitoring Equipment
1. Selling and replacing for Electrocardiogram Monitoring/ Defibrillator/ EGG/ Fetal Monitor Repair and parts.
2. Inspection Judgment/ Chip/Mainboard, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display,Keyboat Plate, Specification PCB, Rotary Knob Maintenrance.
3.Selling and replacing all kinds of PCB, Power Supply, ECG PCB, SPO2 PCB,NIBP PCB, Display,Keyboat Plate, Specification PCB, Rotary Knob.
4.Monitor/ Electrocardiograph for renting,maintenance, guarantee repairing and training.
Included brands: GE, , Spacelabs, Siemens, Mindray, ZOLL, Endoscopy, Tyco, NIHON KOHDEN, , Promeco etc.
Technological advantage: M3001A Part Repairing
Brand | Model |
GE
| DASH1800、DASH2000、DASH2500、DASH3000、DASH4000、 DASH5000、PRO300、PRO400、PRO1000、EAGLE1000、 EAGLE3000、EAGLE4000、SOLAR8000、SOLAR8000i、SOLAR8000M、451N、451SL、450SL TRAM、S/5、Datex-Ohmeda、Cardiocap/5、B40、Transport Pro、MAC500、MAC800、MAC1200、MAC1600、MAC3500、MAC5000、MAC5500、Resonder3000、CARDIOSERV、Corometrics Model 2120is |
| MP20、MP30、MP40、MP50、MP60、MP70(M3000A、M3001A、 M3014A、M3015A、M3016A、M3000-60001、M3000-60002、M3000-60003)、A1、A3、C1、C3、M1723B、M1722A、M4735A、M3535A、M135A、VM4、VM6、VM8、VS3、MP5、M2、M3046A |
Spacelabs
| 1050、90369、91369、Ultraview SL、 90496、91496、mCare300 |
Siemens
| SC60002、SC6000、SC7000、SC60002XL |
Tyco
| NBP40、N595、N600 |
MINDRAY
| PM-7000、PM-8000、PM-9000、MEC-1000、MEC-2000、 PM-7000 Express、PM-8000 Express、PM-9000 Express、PM-60、VS-600、VS-800、VS-900、T5、T6、T8 |
ZOLL
| Defibrillator |
| Radical-7、MS-201、MS-11、MS-7、MS-5 |
| ||
BRAND |
| |
GE | DASH1800,DASH2000,DASH2500,DASH3000,DASH4000,DASH5000, | |
| MP20,MP30,MP40,MP50,MP60,MP70,MP80,MP90,FM20,M4735A,M1351A, | |
NIHON KOHDEN |
| |
Spacelabs | 1050,90369,91369,Ultraview SL, 0496,91496,mCare300 | |
Siemens | SC60002,SC6000,SC7000,SC60002XL | |
Mindray | PM-6000,PM-7000,PM-8000,PM-9000,MEC-1000,MEC-2000, | |
Tyco | NBP4000,NBP4000C | |
| ||
BRAND |
| |
GE | Ohmeda TuffSat ,Ohmeda 3900 | |
Tyco | NBP-40,N-65,NBP-390,N-395,N-550,N-560, | |
Rad-8 SPO2 oximeter ,Radical-7(MS-2011,MS-11,MS-7,MS-5) | ||
NIHON KOHDEN | BSM-1753A
|
二. Ultrasound
New/used/compatible probe/ ultrasound/ PCB for repairing and selling.
Included brands: , GE, Toshiba, Siemens, Medison, Biosound, Hitachi, HP, ATL, ALOKA, etc.
The severice for B Ultrasound probe repairing/ Color Doppler Ultrasound probe repairing are included:
Project Advantages: More 100pcs used B Ultrasound Probe off the shelf for renting and back up.
Ultrasound
| ||
BRAND | MODEL | |
GE | Voluson E6 ,VolusonE8,LOGIQ180,LOGIQ200,LOGIQ400,LOGIQ500,LOGIQ3,LOGIQ5,LOGIQ7,LOGIQ9,LOGIQ E,LOGIQ BOOK XP,VIVID3,VIVID4,VIVID5,,VIVID i, VIVID E9,VIVID 7 | |
IU22,IE33,,D3,HD6,HD7,HD9,HD11,HD15,HD11XE, HDI4000,HDI5000,SONOS4500,SONOS5500,Envisor | ||
SIEMENS | ACUSON X150 ,ACUSON X300,ACUSON X300 PE,SONOLINE G20 ,SONOLINE G40,SONOLINE G50,SONOLINE G60,PRIMIER,Sequoia 512,Acuson CV70,Sonoline Premier(G40),acuson_antares | |
MEDISON |
| |
Mindray | DP3300,DP6600,DP7700,DP8800,DP9900,N80, M5,DC-3, DC-6 | |
ESAOTE | AU3,AU4,AU5,DU3,DU4,DU5,DU8 | |
SONOSITE
| TITAN | |
ALOKA | Prosound SSD-4000,SSD-240,SSD-260,SSD-280, SSD-633,SSD-650,SSD-725,SSD-830,SSD-870,SSD-1000,SSD-1400,SSD-1700,SSD-5000,SSD-7000 | |
Toshiba | SSA-770A,SSA-580,SSH-140,SSA-270A,SSA-340A,SSA-350A,SSA-270,SSH-140A,250A nemio17 |