Large Power Improved Modular UPS System With Bypass Mode Of Good
Performance
Application:
Application IDC(Internet Data Center)
Computing center
ISP (Internet Service Provider )
Telecom , Finance, bank and securities , Tax
Hospital system , industrial automation
Precision equipment, etc.
Working Pricipal:
MOdularUPSusedoubleconversionon-linestructure, including rectifier,
inverter, battery charger, control circuit, the input and the
output battery connector breaker. have function that is input power
factor compensation. All modules can be online hot-swappable,
providing the highest level of availability, and maintainability.
If one power modular failure will not affect the system normal
working, power module can be online hot-swappable all power module
paralel is managed by the control board, in accourdance with the
unified parameters running, one power module fault can be
automatically exit parallel system, will not cause harm to the
whole parallel system.
Modular UPS system use independent static bepass module, do not use
multiple static bypass structure, avoid caused overload damage
modules because of multiple bypass module uneven current when UPS
turn to bypass working. The module parallel output volage accuracy
is ±1%, parallel circulation current<1%.
Static bypass module contains bypass static switch only, excluded
static switch of the amain circuit output; therefore, replacing
static bypass modulewill not cause the system power down or
transfer manual maintenance bypass, which can realize online
hot-swap replacement.
Bypass module
Good performance for bypass module:
Bypass module : 250A(suitable for 150KW system)
Dimension 440×132(3U)×600mm
When use multiple independent small power bypass module will
Produce machine uneven flow caused by bypass module impedance
mismatch , so single static bypass design can avoid this problem
and can use maintenance switch realize hot –swap when repair ups ,
to improve system stability and reliability.
Our Service:
1. 2% spares together with shipment for urgent issue.
2. All of the necessary documents such as drawing, manual etc.
3. We will provide the online service by mail
4. You can get guide from us all the time. We can despatch engineer to assist you solve the problem if
necessary (But you are requested to pay for the cost of ticket,
hotel etc. ). you can despatch engineer(s) to our company to get
training.
5. One year warranty
System | ||
Frequency | 50Hz/60Hz (Settable) | |
Mains Synchronization Range | ±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz | |
Protection Level | IP20 | |
Communication Ports | RS232,RS485,dry contact, SNMP card, EPO, generator port | |
System efficiency | >96% at load above 50%, >95% at load above 25% | |
Operation Temperature | 0-40ºC | |
Storage Temperature | -25ºC~70ºC ( without battery) | |
Humidity | 0-95% (no-condensing) | |
Noise(dB) | 55-62dB,Adjusted with load | |
Weight | module:PM20 | 20KVA power module : 35KG |
module:PM30 | 30KVA power module : 35KG | |
module:PM40 | 40KVA power module : 40KG | |
Dimension (W x D x H)mm | 3 module cabinet | 600X900X1135 |
5 module cabinet(5 battery cabinet option) | 600X1100X2070/ | |
6 module cabinet | 600X900X1535 | |
10 module cabinet | 900X900X2080 | |
power module | 440X650X132(3U)(10KVA/20KVA/30KVA) |
Technical Specifications:
Model | CNM330 20-300KVA | |
Capacity | 20-300KVA | |
Main Input | ||
Input Voltage | 380V/400V/415V | |
Input Frequency Range | 50/60Hz | |
Power Factor | Full load>0.99 ,Half load >0.98 | |
THDi | THDi<3% | |
Input Power Soft-start Function | 5-30s settable | |
Input Voltage Ranges | 228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40% | |
Frequency Range | 40-70HZ | |
Battery | ||
Battery Voltage | ±240VDC(Default),12V Battery 30~40pcs can be choose | |
Charge Voltage Accuracy | ±1% | |
Bypass | ||
Bypass Input Voltage | 380/400/415VAC 3-phase 4-wire | |
Voltage Range | Default value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software | |
Overload Capacity | Long term at 135% rated load ,150%<load<180% more than 10
min, load>1000% 100ms | |
Output | ||
Inverter Output Voltage | 380/400/415VAC 3-phase 4-wire | |
Voltage Accuracy | ±0.5% ( balanced load ) , ±1% ( unbalanced load ) | |
THDV | THDV<1% (linear load) , THDV<3% (nonlinear load) | |
Power Factor | 0.9 | |
Three Phase Angle Accuracy | 120°± 0.5° | |
Current Crest Ratio | 3:1 | |
Overload Capacity | 110%1h,125%10mins,150%1mins,>150%200ms | |
Transfer Time | 0ms,15ms (Eco Mode) |
(Optional South America 208V must be derating use)
Shenzhen Consnant Technology Co., Ltd.
Shenzhen CONSNANT Technology Co., Ltd. (simple name: CONSNANT) is a professional manufacturer engaged in research, development and production of UPS (Uninterruptible Power Supply) including the Modular UPS, Outdoor & Indoor UPS,Industrial special UPS, Low Frequency & High Frequency Online UPS and Solar Power System both for home appliance and telecom equipments.