No. | Item | General Parameter | Remark |
1 | Rated Capacity | 20.0Ah | Standard discharge(0.2 C5)after standard charge(0.2 C5) |
2 | Minimal Rated | 19.5Ah | |
3 | Nominal Voltage | 12.8V | |
4 | Cycle Life | Higher than 60% of the Initial Capacity of the Cells 60%) | Charge: CC@0.2C to 14.6V, then CV till current to 0.05C |
5 | Discharge cut-off voltage | 9.2V | 10.0V( recommended) |
6 | Charging cut-off voltage | 14.8V | 14.6V (recommended) |
7 | Cell and assembly method | IFR26650-3.3AH | 4S6P |
8 | Housing material | PVC |
This module is specially for energy storage system
we can pack this standard module with paralell or series to become
bigger capacity equipment.
For Motorcycle / Replacement Lead Acid Battery Pack
1pcs in each sponge bag
one bag for one little box
8 box for one standard carton
Standard Test Conditions
Test should be conducted with new batteries within one week after shipment from our factory and the batteries shall not be cycled more than five times before the test. Unless otherwise specified, test and measurement shall be done under temperature of 20±5℃ and relative humidity of 45~85%. If it is judged that the test results are not affected by such conditions, the tests may be conducted at temperature 15~30℃ and humidity 25~85%RH.
The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.01mm.
Standard class specified in the national standard or more sensitive class having inner impedance more than 10kΩ/V
Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω.
Impedance shall be measured by a sinusoidal alternating current method (1kHz LCR meter)
Standard Charge/Discharge
Standard Charge : 0.2C
Charging shall consist of charging at a 0.2C constant current rate until the battery reaches 14.6V. The battery shall then be charged at constant voltage of 14.6V volts while tapering the charge current. Charging shall be terminated when the charging current has tapered to 0.05 C5A. Charge time: Approx 7.0h, The battery shall demonstrate no permanent degradation when charged between 0 ºC and 45 ºC.
If no otherwise specified, the rest time between charging and
discharging is 30min.
There shall be no such defect as crack, rust, leakage, which may adversely affect commercial value of battery.
Our Advantage
12V 100ah solar power storage battery
PHOTOS
Guang Zhou Sunland New Energy Technology Co., Ltd.
Guangzhou Sunland New Energy Technology Co., Ltd. (Sunland Power) is a senior professional service provider of
battery application. Aiming at serving industrial users, it is
dedicated to providing industrial users with optimized battery
supporting solutions and safe, environmental friendly and
cost-effective battery products.
It has a R & D, engineering and management team with more than
10 years of industry experience
From upstream to downstream, the battery industry has the advantage
of vertical integration
Specializing in batteries, battery packs, battery management
systems and energy solutions
The products are widely used in medical devices, coal mine
security, electronic appliances, power supply and standby energy
storage system. For example, the power supply system of electric
bicycle; Solar energy storage power supply system, UPS backup power
supply system. At the same time, it is also an ideal choice for
vehicle starting power supply, military painting and other fields.
We provide professional design and customization services according
to the special needs of customers.