NO | Items | Description | |
Normal specification | |||
1 | Nominal Voltage | 12.8V | |
2 | Normal Capacity | 100Ah | |
3 | Internal Resistance | ≤20mΩ | |
Standard Charge | |||
4 | Battery operation temperature range @charging | 0~45℃ | |
5 | Normal charge voltage | 14.6±0.1V | |
6 | Recommended float charge voltage(for Standby use) | 13.9±0.1V | |
7 | Allowed MAX charge current | 80A@Battery initial Temp 25±5℃ | |
8 | Recommended charge current | ≤60A | |
Standard discharge | |||
9 | Battery operation temperature range @discharging | -20~60℃ | |
10 | Output Voltage Range | 8.0~14.6V | |
11 | Allowed discharge current | 100A withstand 30min @Battery initial Temp 25±5℃ | |
12 | Pulse discharge current | 350A withstand 3s | |
13 | Discharge Cut-off voltage | 8.0V | |
Mechanical Characteristics | |||
14 | Dimension | Length 320mm | |
Width 165mm | |||
Height 216mm | |||
15 | Weight | Approx. 12.85Kg | |
Storage | |||
16 | Storage Temperature & Humidity Range | Short: within one month | -20~35℃, 45~75%RH |
Long term: above one month | -10~30℃, 45~75%RH | ||
17 | Self-discharge rate | Residual capacity | ≤3% per month; ≤15% per year |
Reversible capacity | ≤1.5%per month; ≤8% per year |
3. Electrical Characteristics & Test Condition
Testing Conditions: Ambient Temperature: 25±5℃; Huminity:45%~75%.
NO | Items | Criterion | Condition | |
1 | Internal Impedance | ≤20mΩ | Test the internal resistance of 50% SOC battery pack with 1 kHz AC internal resistance test instrument. | |
2 | Capacity | ≥100Ah | Rest for 1 hour after fully charged, then discharge with 0.33C current until the battery reaches the discharge cutoff voltage. Repeat above process for three times, if the discharge time is not less than 180 minutes, you can stop and define the Discharging current*time value (Ah) as battery capacity. | |
3 | Short circuit protection | Automatically cutoff discharging when short circuit, and release after remove the lead. | Connect the positive and negative of this battery pack through a lead with the resistance less than 5mΩ. | |
4 | MAX charge Current | 20A | Charging with this current for more than 0.5h and the added temperature of battery pack less than 20℃. | |
5 | MAX discharge Current | 30A | Discharging with this current for more than 0.5h and the added temperature of battery pack less than 35℃. | |
6 | Cycle life (DOD%100) | ≥2000cycle | Discharge with the current of 0.5C until it can’t discharge, and then rest it for 1h. Charge the battery following CC(0.33C)/CV(14.6V) mode to full capacity, and then rest it for 1h. Repeat above process until full charged capacity is no more than 80% of normal value. Accumulated times is defined as cycle life. | |
7 | Discharge Temperature Characteristics | -20℃ | ≥70% | At 25±5℃ discharge the battery with the current of 0.33C to the cut-off voltage. Store the battery at various temperatures for 2h and discharge the battery with 0.33C to the cut-off voltage. Record the ratio between discharging & charging capacity. |
0℃ | ≥80% | |||
25℃ | 100% | |||
55℃ | ≥95% | |||
8 | Charge Retention ability | remain capacity≥90% | Charge the battery to full capacity and store it for 28days, and then discharge it with 0.33C to the cut-off voltage. |
4. Dimensional Drawing
5.Storage & Transportation
* Based on the character of cell, proper environment for transportation of LiFePO4 battery pack need to be created to protect the battery.
* Battery should be stayed in the ware house -20℃~35℃ where it’s dry, clean, shade, and well-ventilated.
* The battery should be stored in 50% SOC during transportation.
* The battery need to be charged every 6 months if out of use
* Keep the battery against dropping, turning over and serious stacking during loading.
6. Warning & Tips
Please read and follow the specification and caution remarks on battery surface before use the battery. Improper use may cause heat, fire, rupture, damage or capacity deterioration of the battery. Shenzhen Topband Battery Co., Ltd. Describes is not responsible for any accidents caused by the usage without following our specification.
7. Applications
8. Product Processing
9. Why Choose us?
Shenzhen Topband Battery Co., Ltd
Shenzhen Topband Co., Ltd. was registered in so-called “China Silicon Valley”, Shenzhen Hi-tech Industrial Park in 1996, and got listed in Shenzhen Stock Exchange ( the stock code as 002139) in 2007.
After years of rapid development, now Topband takes lithium battery as the core technology and has become one of the leading suppliers of lithium battery solutions in China, focusing on nano lithium iron phosphate/ LiFePO4 technology for EV, RV/ caravan, marine, motorcycle, golf cart / trolly, UPS, solar storage, medical, floor scrubber, industrial, commercial use, etc.
Topband has more than 5000 staffs, covers an area of 100,000 square meters. And large production plants are mainly located at Shenzhen and Huizhou
Our R&D team of over 300 professionals, in cooperation with Tsinghua Research Institute and Harbin Industrial University have laid a firm foundation of our leading technology.
We have got the certificates of ISO9001, ISO14001, OHSAS18001, TS16949 and UL, CE, CB, UN38.3, TUV, etc.
Topband is a Hi-tech enterprise. Since the company established, with innovation, we have committed ourselves to making people’s lives more comfortable and high-efficient. We and our companions are working hard at making technology progress to let people enjoy the changes of new technology.